All Comments (21)
  • @tr_micks
    Yes, would go to Mars and getting through the exam in time
  • brotha, it seems like the beginning of this lesson was cut off...we just jump straight to box calculations after the intro, but without really setting it us as usual. Am i processing this incorrectly?
  • @srlewis76
    For 2023 - equipment grounding conductor fill remains the same as 2020. 2023 - 314.16(B)5 (last sentence): A 1/4 volume allowance shall be made for each additional equipment grounding conductor that enters the box, based on the largest equipment grounding conductor entering the box.
  • I would go to mars. Get a clean slate and get to test my cool ideas where no one else is. I have no fears. Conquering my drug addiction taught me that fear is just being held back by oneself.
  • @notgeo4564
    I feel like week 5 got cut off or there is something missing between weeks 5 and 6. Help Coach!
  • @art-fl8kg
    thank you brotha! this video is so helpful
  • Professor the way you explain everything is so Amazing you have a gift I can believe how clear I can understand every topic thank you so much for your time and big Help.
  • The one way ticket threw me off,one way means you're not coming back,How bout a round trip ticket to Mars so I can come back and tell everyone how it was.💙 My my only fear about taking the test is ,I won't pas on the first try! Thx coach YOU ROCK. When I take my test in March/April and pass ,Can you please give me a shot out.Thz in advance 🙏🏾🙏🏼👍🏾
  • @steveterry54
    I would not go to Mars for any reason. My greatest fear of taking the test is the time it takes to do the back and forth in the book finding answers for questions with which I'm not familiar.
  • at 6:54 your answer for MAX volume should be minimum volume being that is the name of the column...Correct..?
  • @Duzten
    are you counting the first 4 egc"s as 1cu in? its my understanding they count as 1 based off the largest conductor. example. if all conductors are #12, then the first 4 egc's will equal 2.25. not 1.
  • For 2020 EGC you should add 1/4 " to the volume not 1/4 of the conductor
  • @tomedavtube
    First slide about 2020 EGC says says "1/4 INCH" volume for each additional EGC after 4. HOWEVER, 2020 code says: "single VOLUME allowance" up to 4 and "quarter VOLUME allowance" (NOT INCHES) for each additional EGC Confusion with this question: 3#12 Hot + 3#12 Neutral + 1#12 EGC+ 3#14 Hot + 3#14 Neutral = 27.27 Answer '27.75' is based on 2017 code not 2020 Same example If 2020: 3#12 Hot + 3#12 Neutral + 1#12 EGC + .5#12 EGC + 3#14 Hot + 3#14 Neutral = 28.875 Is this correct??? Confusion with this question: 7#12 EGC Discussion says "1/4 INCH" but calculation is based on "1/4 VOLUME" Same with this question: 6#12 Hot + 6#12 Neutral + 6#12 ECG Discussion says "1/4 INCH" but calculation is based on "1/4 VOLUME"
  • @ryanvelez6367
    Lord I hope they allow a calculator in the testing center
  • @amudasesay2396
    Hello Coach, thanks for all the videos. For the 6 EGC #12awg, the first 4 is 2.25. Then 1/4 volume of 2.25 should be 0.5625 and not .25 Please verify, I could be wrong. Thanks
  • ??230.90 deals with overcurrent protection, and doesn't say anything about overhead clearance(47:33 last question)
  • @ryanvelez6367
    Wait here youre talking about a free Exam prep on your website. Is that different from this one?
  • At 29:32 6 #14 should be 2.00 which is 12+ 4.5 for 2 X largest wire which is 2.25...am I right or wrong here..?